Suncenter Max 800 Bar Pressure Gas Booster Pump For Gas Cylinder Transfer And Filling
Here below is the working video of Liquid CO2 pumps.
https://youtu.be/rBq1cFtB48M
Here below is the working video of SLM06 model refrigerant pump.
https://youtu.be/lNK5EXVwTJI
And here below is the working video of gas booster pump:(DGD series)
https://www.youtube.com/watch?v=Ta-LMTcaF8g&feature=youtu.be
And here below is the working video of gas booster pump:(DGT series)
https://youtu.be/kNJIDTkdOHk
Herebelow is the working video of DGS series gas booster system(in Model A blue cabinet).
https://youtu.be/mDlOnlYzRiA
Herebelow is the video of DGS series gas booster system(in Model C frame cabinet).
https://youtu.be/KNIFv-m4-HY
Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:
·Compressed Air driven - no electricity required (connect to normal air compressor)
·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
·No airline lubricator required
·Hydrocarbon free - separation between air and gas sections
·Pressures to 80Mpa (11,600 psi)
·Wide range of models with different ratios
·Built-in-cooling on most models
·Easy to install, operate and maintain
·Best price / performance ratio
·No heat, flame or spark risk and explosion proof
·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
·Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.
Applications for Air Driven Gas Boosters
SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.
As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.
SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.
Applications
·Pressure test with gas
·Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
·Charging of gas cylinder and accumulator with nitrogen
·Supply for isolating gas systems
·Gas assisted injection molding
·Transfer of oxygen cylinders
·Charging of breathing air bottles
·Leak test
·Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
·Safety valve adjusting
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
Technical spcification
Model
|
Pressure
boost ratio
|
Min. gas Inlet
pressure
PA (bar)
|
Max.gas
Inlet
pressure
PA (bar)
|
Max. gas
outlet pressure
PB (bar)
|
Driven air pressure PL
|
Formula to
calculate gas outlet pressure PB
|
Connection:
Gas Inlet /
Gas outlet (NPT thread)
|
Max. flow at driven air pressure of 6bar (L/min)
|
DGA02
|
2:1
|
1.0
|
16
|
16
|
3-8 bar
|
2X PL
|
1/2 / 1/2
|
960 (at PA of 6 bar )
|
DGA05
|
5:1
|
1.5
|
40
|
40
|
3-8 bar
|
5XPL
|
1/2 / 1/2
|
680(at PA of 6 bar )
|
DGA06
|
6:1
|
2.0
|
48
|
48
|
3-8 bar
|
6XPL
|
1/2 / 1/2
|
360(at PA of 10 bar )
|
DGA10
|
10:1
|
3.5
|
80
|
80
|
3-8 bar
|
10XPL
|
3/8/ 3/8
|
210(at PA of 10 bar )
|
DGA25
|
25:1
|
7.0
|
200
|
200
|
3-8 bar
|
25XPL
|
1/4/ 1/4
|
120(at PA of 20 bar )
|
DGA40
|
40:1
|
10
|
320
|
320
|
3-8 bar
|
40XPL
|
1/4/ 1/4
|
200(at PA of 40 bar )
|
DGA60
|
60:1
|
20
|
480
|
480
|
3-8 bar
|
60XPL
|
1/4/ 1/4
|
180(at PA of 40 bar )
|
DGA100
|
100:1
|
25
|
800
|
800
|
3-8 bar
|
100XPL
|
1/4/ M14X1.5
|
136(at PA of 40 bar )
|
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, single stage with double air driven heads type.
·DGD pumps are available with high quality seals, which provide significantly better service life
·Double pump heads with exhaust cooling devices.
·All components in contact with the gas are made of stainless steel.
·Pipes mounting way are available as customized.
Technical specification
Model
|
Pressure
boost ratio
|
Min. gas
Inlet
pressure
PA (bar)
|
Max.gas
Inlet
pressure
PA (bar)
|
Max. gas
outlet pressure
PB (bar)
|
Driven air pressure PL
|
Formula to
calculate gas outlet pressure PB
|
Connection:
Gas Inlet /
Gas outlet (NPT thread)
|
Max. flow at driven air pressure of 6bar (L/min)
|
DGD10
|
10:1
|
3.5
|
80
|
80
|
3-8 bar
|
10XPL+ PA
|
3/8/3/8
|
410(at PA of 6 bar )
|
DGD25
|
25:1
|
10
|
200
|
200
|
3-8 bar
|
25XPL+ PA
|
1/4/1/4
|
396(at PA of 20 bar )
|
DGD40
|
40:1
|
15
|
320
|
320
|
3-8 bar
|
40XPL+ PA
|
1/4/1/4
|
320(at PA of 40 bar )
|
DGD60
|
60:1
|
25
|
480
|
480
|
3-8 bar
|
60XPL+ PA
|
1/4/1/4
|
215(at PA of 40 bar )
|
DGD100
|
100:1
|
35
|
800
|
800
|
3-8 bar
|
100XPL+ PA
|
1/4/M14*1.5
|
300(at PA of 60 bar )
|
DGD130
|
130:1
|
50
|
1040
|
1040
|
3-8 bar
|
130XPL+ PA
|
1/4/M14*1.5
|
180(at PA of 60 bar )
|
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
·DGT pumps are available with high quality seals, which provide significantly better service life
·Double pump heads with exhaust cooling devices.
·All parts in contact with the gas are made of stainless steel.
Technical specification
Model
|
Pressure
boost ratio
|
Min. gas
Inlet
pressure
PA (bar)
|
Max.gas
Inlet
pressure
PA (bar)
|
Max. gas
outlet pressure
PB (bar)
|
Driven air pressure PL
|
Formula to
calculate gas outlet pressure PB
|
Connection:
Gas Inlet /
Gas outlet (NPT thread)
|
Max. flow at driven air pressure of 6bar (L/min)
|
DGT25
|
25:1
|
1
|
10
|
200
|
3-8 bar
|
25XPL+3.5XPA
|
3/8/ 1/4
|
136(at PA of 8 bar )
|
DGT40
|
40:1
|
1
|
10
|
320
|
3-8 bar
|
40XPL+ 6XPA
|
3/8/ 1/4
|
124(at PA of 8 bar )
|
DGT10/60
|
10:1/60:1
|
1
|
10
|
480
|
3-8 bar
|
60XPL+6X PA
|
3/8/ 1/4
|
84(at PA of 8 bar )
|
DGT25/60
|
25:1/60:1
|
10
|
25
|
480
|
3-8 bar
|
60XPL+2.5XPA
|
3/8/ 1/4
|
80(at PA of 15 bar )
|
DGT100
|
100:1
|
1
|
10
|
800
|
3-8 bar
|
100XPL+10XPA
|
3/8/ M14*1.5
|
63(at PA of 8 bar )
|
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Should the gas booster pumps caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.
air booster
air pressure booster
air booster pump
pneumatic pressure booster
compressed air pressure booster
air pressure booster pump
pneumatic pressure intensifier
compressed air booster pump
pneumatic booster pump
compressed air pressure booster systems
air pressure booster system
gas booster
gas booster pump
gas pressure booster
gas pressure pump
gas booster system
air driven gas booster
gas pressure booster pump
gas booster pump price
air pressure pump
pressure air pump
high pressure air booster
Pneumatic (Air compressor driven) gas booster pump system
Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System
Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).
Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.
Applications
Pressure test with gas
Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
Charging of gas cylinder and accumulator with nitrogen
Supply for isolating gas systems
Gas assisted injection molding
Transfer of oxygen cylinders
Charging of breathing air bottles
Leak test
Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
Safety valve adjusting
Technical specification for DGS-DGA series
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Technical specification for DGS-DGD series
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar